Vibration monitor can be used in ATEX zones September 1st 2007 The efector octavis bearing
condition monitor from ifm
electronic is now available
with ATEX equipment category
3D/3G and is therefore suitable for
zone 22 or zone 2 explosionhazard
areas. Units are also rated
at IP69K, making them suitable for
the wettest of applications.
The device continuously
monitors the machine's operating
condition, detects rolling element
bearing failures and shaft
imbalance conditions on critical
plant equipment such as pumps,
motors, mixers, compressors, fans
and spindles.
Octavis is permanently mounted
on the equipment and has the
processing capability to analyse a
vibration signature and to predict
failures by sending an alarm output
signal to a PLC or relay. This can
help optimise machine availability
and plant up-time.
The efector octavis incorporates
an accelerometer, analog-to-digital
converter, digital signal processor
and diagnostic electronics in a
compact 40 by 40mm package. More articles from ifm electronic Limited: |